Brand Name: Grundfos

Model Number: SLV.65.65 .09.2.1.502

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: Negotiable price

Packaging Details: Wooden box

Delivery Time: 10--60 workdays

Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability: 100

Get Best Price
Highlight:

Grundfos SLV wastewater pump

,

Grundfos SLV centrifugal pump

,

Grundfos SLV Non self suction pump

Maximum Head::
17m
Maximum Traffic::
20 L/S
Working Pressure::
6 Bar
Liquid Temperature Range:
0 - 40 °C
Liquid Temperature During Operation:
20 °C
Density:
998.2 Kg/m³
Pipe Connection:
DN 50
Power Supply Frequency:
50 Hz
Rated Voltage:
1 X 230 V
Number Of Motor Poles:
2
Maximum Head::
17m
Maximum Traffic::
20 L/S
Working Pressure::
6 Bar
Liquid Temperature Range:
0 - 40 °C
Liquid Temperature During Operation:
20 °C
Density:
998.2 Kg/m³
Pipe Connection:
DN 50
Power Supply Frequency:
50 Hz
Rated Voltage:
1 X 230 V
Number Of Motor Poles:
2
Grundfos SLV Non Self Suction Single-stage Centrifugal Pump For Treating Wastewater Production Water Unfiltered Raw Sewage
SLV.65.65.09.2.1.502


This non - self - priming single - stage centrifugal pump is designed for handling wastewater, production water, and unfiltered raw sewage. It is designed for intermittent and continuous operation with submersible installation. The highly efficient SuperVortex impeller can handle long fibers and solids with a size of 65 millimeters, and is suitable for wastewater with a dry matter content of up to 5%. The unique stainless - steel clamp assembly system enables the pump to be quickly and conveniently detached from the motor unit, facilitating maintenance and inspection. No specialized tools are required.
 

Submersible Sewage Pump
SLV.65.65.09.2.1.502
Number: 96115119

Suitable for

  • Commercial Sewage Treatment
  • Industrial Wastewater
  • Sewage Transportation
  • Flood Control and Drainage

Submersible Grundfos SL sewage pumps (with a power range of 0.9-1.5 kW) are equipped with either a channel impeller (SL1) or a Super Vortex impeller (SLV). The unobstructed passage diameter through the pump ranges from 50 to 65 mm, which depends on the size of the pump.
Grundfos SLV Non Self Suction Single-stage Centrifugal Pump For Treating Wastewater Production Water Unfiltered Raw Sewage 0


Controller:
Humidity Sensor: No humidity sensor
Capacitive Sensor for Detecting Impurities in the Liquid: No oil and water content sensor
AUTOADAPT: No


Liquid:
Liquid Temperature Range: 0 - 40 °C
Liquid Temperature during Operation: 20 °C
Density: 998.2 kg/m³


Technology:
Rated Flow Rate: 4.38 liters per second
Maximum flow: 6.81 liters per second
Rated Head: 3.49 meters
Type of impeller: SUPER VORTEX
Max. Particle: 65 millimeters
Main Shaft Seal: SiC/SiC
Approvals: EN 12050-1
Explosion approval: No
Curve tolerance: ISO9906:2012 3B2
Cooling jacket (Yes/No): No


Materials:
Pump Casing: Cast iron
Pump housing: EN-GJL-250
Impeller: Cast iron
EN-GJS-400-15
Motor house: Cast iron
Motor: EN 1561 EN-GJL-200
Motor house: ASTM A48 35B
Secondary shaft seal: LIP SEAL, NBR


Installation:
Ambient Temperature Range: 0 - 40 °C
Maximum Operating Pressure: 6 bar
Type of outlet connection: DIN
Outlet Size: DN 65
Pressure rating for pipe connection: PN 10
Maximum installation depth: 7 meters
Auto coupling: 96090992


Electrical Data:
Power input P1: 1.3 kW
Rated power - P2: 0.9 kW
Power Supply Frequency: 50 Hz
Rated voltage: 1 x 230 V
Positive Tolerance of U: 6 %
U -tolerance: -10 %
Maximum Number of Starts per Hour: 30
Rated current: 6.1 A
Rated current at 3/4 load: 5.1 A
Rated current at 1/2 load: 4.1 A
Starting Current: 38 A
No-load Rated Current: 2.6 A
Cos phi - Power Factor: 0.96
Cos phi - Power Factor at 3/4 Load: 0.92
Cos phi - Power Factor at 1/2 Load: 0.86
Rated driver speed: 2870 revolutions per minute
Locked Rotor Torque: 6.5 Nm
Moment of Inertia: 0.0032 kg m²
Motor Efficiency at Full Load: 67 %
Motor Efficiency at 3/4 Load: 63 %
Motor Efficiency at 1/2 Load: 55 %
Capacitor Size - Operation: 30 µF
Number of Motor Poles: 2
Starting Method: Direct-on-line (DOL)
Enclosure Rating (IEC 34-5): IP68
Insulation class (IEC 85): F
Self-protection Standard: PTO
Cable type: H07RN-F
Length of power cable: 10 meters
Power plug: No plug


Others:
Net Weight: 46.5 kg
Gross weight: 51.8 kg

Grundfos SLV Non Self Suction Single-stage Centrifugal Pump For Treating Wastewater Production Water Unfiltered Raw Sewage 1
Grundfos SLV Non Self Suction Single-stage Centrifugal Pump For Treating Wastewater Production Water Unfiltered Raw Sewage 2
Grundfos SLV Non Self Suction Single-stage Centrifugal Pump For Treating Wastewater Production Water Unfiltered Raw Sewage 3
Grundfos SLV Non Self Suction Single-stage Centrifugal Pump For Treating Wastewater Production Water Unfiltered Raw Sewage 4
Grundfos SLV Non Self Suction Single-stage Centrifugal Pump For Treating Wastewater Production Water Unfiltered Raw Sewage 5